The vehicle-mounted spectrum monitoring and direction-finding equipment monitors radio signals in a specific area, capturing technical parameters such as frequency offset, field strength, and emission bandwidth.
Contact
Product Introduction

The vehicle-mounted spectrum monitoring and direction-finding equipment monitors radio signals in a specific area, capturing technical parameters such as frequency offset, field strength, and emission bandwidth. This enables the rapid detection of illegal signals and other non-compliant signals. The equipment covers various frequency ranges to meet diverse customer needs. It integrates radio signal monitoring and direction-finding functionalities into one unit, making it suitable for vehicle installation and setup, providing strong mobility and flexibility.



Product Features

1. Wide and Narrow Band Design: Adapts to high-speed, dense, and complex electromagnetic signal overlapping scenarios.

 

2. RF Integrated Design: With the RF front end moved forward, this design reduces insertion loss and enhances sensitivity.


Specifications

Frequency Range

30MHz~3GHz

30MHz~8GHz

30MHz~18GHz

30MHz~50GHz

Direction-Finding System

Correlative Interferometer

IF Bandwidth

80MHz/500MHz;

Scanning Speed

100GHz/s(25kHz Step forward)

Direction-Finding Accuracy

≤1.5°(RMS)

≤2°(RMS)

≤2.5°(RMS)

≤2.5°(RMS)

Single-site Positioning Error

≤ R × 8% (CEP, open unobstructed field, where R is slant range)

Direction-Finding Sensitivity

≤ 32dBμV/m

≤ 35dBμV/m

≤ 35dBμV/m

≤45dBμV/m

Max Hopping Rate Suitable for Frequency Hopping Signals

5000 hops/s(30MHz~8GHz)

Types of Detectable Signals

Communication, radar, navigation, and self-identification signals.

Modulation Style Recognition Accuracy

AM、FM、CW、ASK、2FSK、4FSK、BPSK、QPSK、8PSK、16QAM、MSK,the modulation style recognition accuracy is≥85%(SNR≥12dB)

Pulse Width Measurement Range

0.2μs~4000μs

Pulse Repetition Interval Measurement Range

2μs~10ms

Power Supply

AC 220V±10%,50Hz±5%

Operating Temperature

-40~+55°C